38 research outputs found

    Microbotanical residues for the study of early hominin tools

    Full text link
    More than 2 million years ago in East Africa, the earliest hominin stone tools evolved amidst changes in resource base, with pounding technology playing a key role in this adaptive process. Olduvai Gorge (now Oldupai) is a famed locality that remains paramount for the study of human evolution, also yielding some of the oldest battering tools in the world. However, direct evidence of the resources processed with these technologies is lacking entirely. One way to obtain this evidence is through the analysis of surviving residues. Yet, linking residues with past processing activities is not simple. In the case of plant exploitation, this link can only be established by assessing site-based reference collections inclusive of both anthropogenic and natural residues as a necessary first step and comparative starting point. In this paper, we assess microbotanical remains from rock clasts sourced at the same quarry utilized by Oldowan hominins at Oldupai Gorge. We mapped this signal and analysed it quantitatively to classify its spatial distribution objectively, extracting proxies for taxonomic identification and further comparison with freestanding soils. In addition, we used blanks to manufacture pounding tools for blind, controlled replication of plant processing. We discovered that stone blanks are in fact environmental reservoirs in which plant remains are trapped by lithobionts, preserved as hardened accretions. Tool use, on the other hand, creates residue clusters; however, their spatial distribution can be discriminated from purely natural assemblages by the georeferencing of residues and statistical analysis of resulting patterns. To conclude, we provide a protocol for best practice and a workflow that has the advantage of overcoming environmental noise, reducing the risk of false positive, delivering a firm understanding of residues as polygenic mixtures, a reliable use of controls, and most importantly, a stronger link between microbotanical remains and stone tool use

    Frequency- and time-resolved photocurrents in vacuum-deposited stabilised a-Se films: the role of valence alternation defects

    Get PDF
    From Springer Nature via Jisc Publications RouterHistory: received 2020-06-08, registration 2020-07-25, accepted 2020-07-25, pub-electronic 2020-08-19, online 2020-08-19, pub-print 2020-09Publication status: PublishedFunder: The Royal Society (London); Grant(s): IE160035Funder: Natural Sciences and Engineering Council of Canada; Grant(s): Discovery GrantFunder: Engineering and Physical Sciences Research Council; doi: http://dx.doi.org/10.13039/501100000266; Grant(s): NS/A000055/1Abstract: Stabilised amorphous selenium (a-Se) is currently used in the majority of direct conversion mammographic X-ray imaging detectors due to its X-ray photoconductivity and its ability to be uniformly deposited over large area TFT substrates by conventional vacuum deposition. We report experimental results on photocurrent spectroscopy (frequency-resolved spectroscopy (FRS) and single-time transients), on vacuum-deposited a-Se films. We show that all measured photocurrents depend critically on the relative time spent by the material in the light and in the dark. We identify that the observed pronounced variation in optical response depends on the density of trapped (optically injected) charge within 200 nm of the surface and show that it is the ratio of dark and light exposure time that controls the density of such charge. Our data confirm that the localised charge radically influences the photocurrent transient shape due to the effective screening of the applied field within 200 nm of the surface. The field modification occurs over the optical extinction depth and changes both the photogeneration process and the drift of carriers. Many aspects of our data carry the signature of known properties of valence alternation pair (VAP) defects, which control many properties of a-Se. Modelling in the time domain shows that light generation of VAPs followed by optically triggered VAP defect conversion can lead to near-surface charge imbalance, demonstrating that VAP defects can account for the unusual optical response. The stabilised a-Se films were deposited above the glass transition temperature of the alloy with composition a-Se:0.3% As doped with ppm Cl. Electron paramagnetic resonance measurements at temperatures down to 5 K did not detect any spin active defects, even under photoexcitation above band gap

    Amorphous and Polycrystalline Photoconductors for Direct Conversion Flat Panel X-Ray Image Sensors

    Get PDF
    In the last ten to fifteen years there has been much research in using amorphous and polycrystalline semiconductors as x-ray photoconductors in various x-ray image sensor applications, most notably in flat panel x-ray imagers (FPXIs). We first outline the essential requirements for an ideal large area photoconductor for use in a FPXI, and discuss how some of the current amorphous and polycrystalline semiconductors fulfill these requirements. At present, only stabilized amorphous selenium (doped and alloyed a-Se) has been commercialized, and FPXIs based on a-Se are particularly suitable for mammography, operating at the ideal limit of high detective quantum efficiency (DQE). Further, these FPXIs can also be used in real-time, and have already been used in such applications as tomosynthesis. We discuss some of the important attributes of amorphous and polycrystalline x-ray photoconductors such as their large area deposition ability, charge collection efficiency, x-ray sensitivity, DQE, modulation transfer function (MTF) and the importance of the dark current. We show the importance of charge trapping in limiting not only the sensitivity but also the resolution of these detectors. Limitations on the maximum acceptable dark current and the corresponding charge collection efficiency jointly impose a practical constraint that many photoconductors fail to satisfy. We discuss the case of a-Se in which the dark current was brought down by three orders of magnitude by the use of special blocking layers to satisfy the dark current constraint. There are also a number of polycrystalline photoconductors, HgI2 and PbO being good examples, that show potential for commercialization in the same way that multilayer stabilized a-Se x-ray photoconductors were developed for commercial applications. We highlight the unique nature of avalanche multiplication in a-Se and how it has led to the development of the commercial HARP video-tube. An all solid state version of the HARP has been recently demonstrated with excellent avalanche gains; the latter is expected to lead to a number of novel imaging device applications that would be quantum noise limited. While passive pixel sensors use one TFT (thin film transistor) as a switch at the pixel, active pixel sensors (APSs) have two or more transistors and provide gain at the pixel level. The advantages of APS based x-ray imagers are also discussed with examples

    Roadmap on chalcogenide photonics

    Get PDF
    Alloys of sulfur, selenium and tellurium, often referred to as chalcogenide semiconductors, offer a highly versatile, compositionally-controllable material platform for a variety of passive and active photonic applications. They are optically nonlinear, photoconductive materials with wide transmission windows that present various high- and low-index dielectric, low-epsilon and plasmonic properties across ultra-violet, visible and infrared frequencies, in addition to an, non-volatile, electrically/optically induced switching capability between phase states with markedly different electromagnetic properties. This roadmap collection presents an in-depth account of the critical role that chalcogenide semiconductors play within various traditional and emerging photonic technology platforms. The potential of this field going forward is demonstrated by presenting context and outlook on selected socio-economically important research streams utilizing chalcogenide semiconductors. To this end, this roadmap encompasses selected topics that range from systematic design of material properties and switching kinetics to device-level nanostructuring and integration within various photonic system architectures

    Infected pancreatic necrosis: outcomes and clinical predictors of mortality. A post hoc analysis of the MANCTRA-1 international study

    Get PDF
    : The identification of high-risk patients in the early stages of infected pancreatic necrosis (IPN) is critical, because it could help the clinicians to adopt more effective management strategies. We conducted a post hoc analysis of the MANCTRA-1 international study to assess the association between clinical risk factors and mortality among adult patients with IPN. Univariable and multivariable logistic regression models were used to identify prognostic factors of mortality. We identified 247 consecutive patients with IPN hospitalised between January 2019 and December 2020. History of uncontrolled arterial hypertension (p = 0.032; 95% CI 1.135-15.882; aOR 4.245), qSOFA (p = 0.005; 95% CI 1.359-5.879; aOR 2.828), renal failure (p = 0.022; 95% CI 1.138-5.442; aOR 2.489), and haemodynamic failure (p = 0.018; 95% CI 1.184-5.978; aOR 2.661), were identified as independent predictors of mortality in IPN patients. Cholangitis (p = 0.003; 95% CI 1.598-9.930; aOR 3.983), abdominal compartment syndrome (p = 0.032; 95% CI 1.090-6.967; aOR 2.735), and gastrointestinal/intra-abdominal bleeding (p = 0.009; 95% CI 1.286-5.712; aOR 2.710) were independently associated with the risk of mortality. Upfront open surgical necrosectomy was strongly associated with the risk of mortality (p < 0.001; 95% CI 1.912-7.442; aOR 3.772), whereas endoscopic drainage of pancreatic necrosis (p = 0.018; 95% CI 0.138-0.834; aOR 0.339) and enteral nutrition (p = 0.003; 95% CI 0.143-0.716; aOR 0.320) were found as protective factors. Organ failure, acute cholangitis, and upfront open surgical necrosectomy were the most significant predictors of mortality. Our study confirmed that, even in a subgroup of particularly ill patients such as those with IPN, upfront open surgery should be avoided as much as possible. Study protocol registered in ClinicalTrials.Gov (I.D. Number NCT04747990)

    Intraperitoneal drain placement and outcomes after elective colorectal surgery: international matched, prospective, cohort study

    Get PDF
    Despite current guidelines, intraperitoneal drain placement after elective colorectal surgery remains widespread. Drains were not associated with earlier detection of intraperitoneal collections, but were associated with prolonged hospital stay and increased risk of surgical-site infections.Background Many surgeons routinely place intraperitoneal drains after elective colorectal surgery. However, enhanced recovery after surgery guidelines recommend against their routine use owing to a lack of clear clinical benefit. This study aimed to describe international variation in intraperitoneal drain placement and the safety of this practice. Methods COMPASS (COMPlicAted intra-abdominal collectionS after colorectal Surgery) was a prospective, international, cohort study which enrolled consecutive adults undergoing elective colorectal surgery (February to March 2020). The primary outcome was the rate of intraperitoneal drain placement. Secondary outcomes included: rate and time to diagnosis of postoperative intraperitoneal collections; rate of surgical site infections (SSIs); time to discharge; and 30-day major postoperative complications (Clavien-Dindo grade at least III). After propensity score matching, multivariable logistic regression and Cox proportional hazards regression were used to estimate the independent association of the secondary outcomes with drain placement. Results Overall, 1805 patients from 22 countries were included (798 women, 44.2 per cent; median age 67.0 years). The drain insertion rate was 51.9 per cent (937 patients). After matching, drains were not associated with reduced rates (odds ratio (OR) 1.33, 95 per cent c.i. 0.79 to 2.23; P = 0.287) or earlier detection (hazard ratio (HR) 0.87, 0.33 to 2.31; P = 0.780) of collections. Although not associated with worse major postoperative complications (OR 1.09, 0.68 to 1.75; P = 0.709), drains were associated with delayed hospital discharge (HR 0.58, 0.52 to 0.66; P < 0.001) and an increased risk of SSIs (OR 2.47, 1.50 to 4.05; P < 0.001). Conclusion Intraperitoneal drain placement after elective colorectal surgery is not associated with earlier detection of postoperative collections, but prolongs hospital stay and increases SSI risk

    High-power-load DCLM monochromator for a computed tomography program at BMIT at energies of 25-150 keV

    Get PDF
    The research program at the biomedical imaging facility requires a high-flux hard-X-ray monochromator that can also provide a wide beam. A wide energy range is needed for standard radiography, phase-contrast imaging, K-edge subtraction imaging and monochromatic beam therapy modalities. The double-crystal Laue monochromator, developed for the BioMedical Imaging and Therapy facility, is optimized for the imaging of medium- and large-scale samples at high energies with the resolution reaching 4 mu m. A pair of 2mm-thick Si(111) bent Laue-type crystals were used in fixed-exit beam mode with a 16mm vertical beam offset and the first crystal water-cooled. The monochromator operates at energies from 25 to 150keV, and the measured size of the beam is 189mm (H)x8.6mm (V) at 55m from the source. This paper presents our approach in developing a complete focusing model of the monochromator. The model uses mechanical properties of crystals and benders to obtain a finite-element analysis of the complete assembly. The modeling results are compared and calibrated with experimental measurements. Using the developed analysis, a rough estimate of the bending radius and virtual focus (image) position of the first crystal can be made, which is also the real source for the second crystal. On the other hand, by measuring the beam height in several points in the SOE-1 hutch, the virtual focus of the second crystal can be estimated. The focusing model was then calibrated with measured mechanical properties, the values for the force and torque applied to the crystals were corrected, and the actual operating parameters of the monochromator for fine-tuning were provided.Peer reviewe

    Data of low-dose phase-based X-ray imaging for in situ soft tissue engineering assessments

    No full text
    This article presents the data of using three phase-based X-ray imaging techniques to characterize biomaterial scaffold and soft tissues in situ, as reported in our study “Low-dose phase-based X-ray imaging techniques for in situ soft tissue engineering assessments” [1]. The examined parameters include the radiation dose, scan time, and image quality, which are all critical to longitudinal in situ live animal assessments. The data presented were obtained from three dimensional imaging of scaffolds in situ cartilage by means of synchrotron-based computed tomography-diffraction enhanced imaging (CT-DEI), analyzer based imaging (CT-ABI), and in-line phase contrast imaging (CT-PCI) at standard and low dose imaging modalities

    Tvorba jednorozměrného van der Waalsova krystalu selenu z trojrozměrné amorfní fáze: Spektroskopický podpis van der Waalsovy vazby

    No full text
    Trigonal selenium is a prototypical one-dimensional (1D) van der Waals (vdW) solid, where covalently bonded helical chains are held together by weaker vdW forces. In this work, we have studied structural transformation from a three-dimensional amorphous phase of non-interacting Se chains into a 1D vdW crystal using x-ray absorption spectroscopy. The crystallization process and establishment of vdW interaction are accompanied by elongation and weakening of covalent Se-Se bonds. We have found a unique signature in the x-ray absorption near-edge structure spectrum that is associated with vdW bonds and can be used to identify the formation of the latter. We believe that a similar approach can be used to study other 1D vdW solids, such as transition-metal trichalcogenides, and particularly stress the usefulness of x-ray absorption spectroscopy to identify vdW bonds.Trigonální selen je typická jednorozměrná (1D) van der Waalsova (vdW) pevná látka, kde jsou kovalentně vázané spirálové řetězce drženy pohromadě slabšími vdW silami. V této práci jsme studovali strukturální transformaci z trojrozměrné amorfní fáze neinteragujících Se řetězců na 1D vdW krystal pomocí rentgenové absorpční spektroskopie. Proces krystalizace a vytvoření interakce vdW jsou doprovázeny prodlužováním a zeslabováním kovalentních vazeb Se-Se. Našli jsme jedinečný podpis ve spektru rentgenové absorpční hrany, který je spojen s vdW vazbami a může být použit k identifikaci jejich tvorby. Domníváme se, že podobný přístup lze použít ke studiu jiných 1D pevných látek 1D s vdW, jako jsou trichalkogenidy přechodných kovů, a zvláště zdůrazňujeme užitečnost rentgenové absorpční spektroskopie k identifikaci vdW vazeb
    corecore